167 tools. One engineering assistant.
TAIPilot covers the work you do in TIA Portal every day — from blocks and tags to hardware, HMI, alarms, tests and documentation. Each area below lists the main tools the AI uses.
PLC programming: SCL, LAD, FBD
The AI works with your program as text where it can (SCL, DB, STL sources) and generates LAD/FBD networks from a simple description where it must.
- Export and import SCL, DB, STL and UDT sources; overwrite safely and compile with the full error list
- Generate LAD and FBD blocks and append networks from logic expressions
- Edit block interfaces, tag tables, constants, watch and force tables
- Bulk tags from Excel/CSV, rename a tag or DB member everywhere — PLC and HMI
- Software units, namespaces and relations (on CPUs that support them)
- Unit clone generator: S1 → S8 with tags, DBs, HMI tags, alarms and screens, with undo
- Code check with configurable naming, documentation and style rules
Hardware & networks
Configure the hardware tree from the catalogue and keep networks consistent without hunting through property pages.
- Find catalogue items by article number or description; add CPUs, IO devices and modules
- IO addresses, IP addresses, PROFINET names, subnets and port topology
- Change a CPU type or firmware while keeping the configuration
- Export/import hardware as AutomationML; GSD parameters and I-Device GSDML
- Technology objects: PID, speed and positioning axes, encoders
- OPC UA server interfaces and nodesets
HMI: WinCC Unified
Build and maintain Unified screens through Openness, then let the AI check that every HMI tag still points at something real in the PLC.
- Create and edit screens and items, copy screens, set up navigation and faceplates
- HMI tags, connections, discrete and analog alarms, alarm classes, logging
- SVG preview of Unified screens, so the AI can review layouts
- Compile and validate the HMI like the TIA command
- PLC ↔ HMI impact analysis: where is this tag used, what breaks if I rename it?
- Consistency check: broken, unused or mistyped HMI tags
PLCSIM testing
Turn requirements into tests that drive inputs and check outputs cycle by cycle in S7-PLCSIM Advanced — deterministic, repeatable, documented.
- Create and start PLCSIM Advanced instances; download hardware and software
- Read and write tags by symbolic name
- Logic tests: set inputs, run N cycles with virtual time, assert outputs and DB values
- Online, read-only: go online, status, compare offline vs. online
- Download to a real PLC only with an explicit interface and confirmation
Automatic acceptance builds on these tools: requirements from your spec (tia_requirements), test suites and FAT reports with trajectory charts (tia_test_suite), plant models for virtual commissioning (tia_plant_model).
Alarms & diagnostics
Keep alarm texts, classes and supervisions consistent across sections and languages without editing Excel by hand.
- Export/import PLC alarms in TIA's own Excel formats
- Alarm text lists with entries and value ranges
- ProDiag supervisions in FB and UDT interfaces; ProDiag FBs and assignments
- System diagnostics settings
Recipes & project texts
Manage recipe data and translations as structured data the AI can generate, check and re-import.
- PLC recipes (Pro): record UDT + recipe DB, create, read and edit records
- Project languages and multilingual project texts for translation
- HMI text lists and graphic lists
Safety & security (read-mostly)
See the safety and security state of a project at a glance. Changes to safety are deliberately limited and always explicit.
- Read-only safety summary: signatures, F-blocks, F-parameters
- F-parameter changes with dry run by default
- UMAC users and roles, device access protection (read-only)
- Heuristic security audit of the project
- Know-how protection and the PLC configuration password via a Windows credential dialog
Documentation, compare & git
Treat the PLC project like code: diffable sources in git, readable reports and documentation generated from the real project.
- Export the whole program to a folder for git, and import it back
- TIA Version Control Interface workspaces
- Compare PLCs, hardware, libraries and single blocks (text diff)
- Cross references, code search, unused objects
- Reports (signals, blocks, hardware) in Excel or Markdown; project documentation for handover
Built for real engineering PCs
Tool profiles
Show the AI only the tool groups a task needs (PLC, HMI, hardware, review) — less context, better tool choice.
stdio and HTTP
Claude starts TAIPilot locally over stdio. Optional Streamable HTTP on 127.0.0.1 with per-client API keys.
Watchdog
If TIA Portal shows a modal dialog, the call times out cleanly and the AI is told to ask you to check TIA.
Control panel
A tray app for profiles, the HTTP server, API keys, the license, the audit log and policies.
Audit log
Every call — client, tool, arguments summary, result, duration, objects — in a hash-chained log you can verify and export.
Policies
Read-only mode, allowed groups, denied tools, protected objects, PLCSIM-only download. Per machine and per project.
Shipped — and what comes next
Automatic acceptance
Specification in, FAT report out: requirements are read from your spec, linked to PLCSIM tests and reported with a traceability matrix and trajectory charts.
Virtual commissioning
Plant models — tanks, valves, pumps, pressures — answer the PLC in PLCSIM tests, so sequences are tested end to end before site.
Safe changes
Every write is recorded as a change set: readable diff, human approval for risky steps and rollback.
TIA Portal V17–V20
Builds for TIA Portal V17, V18, V19 and V20 are in preparation. Today TAIPilot supports TIA Portal V21.